{"title":"Duplex Control Panels","description":"\u003cp data-mce-fragment=\"1\"\u003eDuplex panels are utilized to control two pumps simultaneously. These panels are often configured such that each pump will take turns as the primary pump. This means that the control panel will alternate which pump will be activated first for each cycle.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eControl panels have two main functions. Their first function is to provide a location to joint electrical equipment to a power source. To do that safely, these units are weather resistant to protect their electrical circuits from the elements. Their second function is to organize and manage the systems they power. Various models will have different approaches for the second function, but all control panels will serve those two functions.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLift stations are the most common location for these control panels. These panels allow the station to alternate between pumps, so that one pump does not wear significantly sooner than the other. Additionally, these control panels can activate the second pump if the flow rate into the system is too fast or if the first pump has failed. This allows the lift station to continue to accommodate high flow rates and continue to operate after a pump malfunctions.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eControl panels that do not use a timer for their effluent pump are called “on demand” panels. This is because the pump is activated whenever it is needed. A float switch is most often used to activate and deactivate the pump.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDosing timers are the most common type of timer found on duplex control panels. That type of timer allows the operator to control how long the pumps are activated and how long they are deactivated. The dosing timer will allow power to the pumps for a set interval and disconnect power from the pumps for a prescribed amount of time.\u003c\/p\u003e","products":[{"product_id":"r2115-duplex-control-panel","title":"Duplex Control Panel RJR-DCP-ALTDMDLA","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e \n\u003cp\u003eIf you’re in the market for an innovative sewage and wastewater control panel, the Duplex panel RJR-DCP-ALTDMDLA may be for you. The Duplex panel RJR-DCP-ALTDMDLA will monitor and control the pumps automatically when it is set up. This will keep your pumps working as efficiently as possible, with the least amount of maintenance work possible.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA has two independent breaker rows for each pump. That way if one pump malfunctions, it should not affect the second. The panel also comes with an alarm that will alert you if there is a high amount of water in the panel or a malfunctioning pump. The panel also comes with a pump test switch to monitor if the pumps are functioning properly.\u003c\/p\u003e\n\u003cp\u003eThe warning light is 360-Degrees, so you will know of an issue regardless of where the Duplex panel RJR-DCP-ALTDMDLA is placed. The panel also has run indicator lights, so you will know the panel itself is functioning properly. If there is an issue with the panel or the pumps, there is a high decibel alarm buzzer that will ring at an ear-piercing 95 dB. Once you hear of see the alarm, there is an override circuit for testing pumps. There are also control and alarm circuit fuses.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA includes an automatic alternating relay, which alternates between which pump runs the cycle. It also includes three mechanical float switches: One Pump Hand, off, and Auto toggle.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA typically boasts an excellent life span. However, if any problems arise there is a Two Year Warranty included with your purchase!\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eYou (the customer) are responsible for making sure you are following all applicable laws and regulations in your area before replacing your septic air pump yourself. Duplex panel for RJR-DCP-ALTDMDLA are Registered Trademarks of duplex panel. Under no circumstances is Wholesale Septic Supply representing to the general public that it is an Authorized Distributor, Dealer, or is affiliated with those companies with whom we make product comparisons or with any products we sell.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eP\/N RJR-DCP-ALTDMDLA\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":5376744521756,"sku":"RJR-DCP-ALTDMDLA","price":725.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/CONTROL_PANEL_003.jpg?v=1558639046"},{"product_id":"altd2hpdv-dosing-220v-120v-duplex-control-panel","title":"Grinder Duplex Dosing Timer Control Panel 220V\/120V ALTD2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cp\u003eThis control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control. The pump operation is controlled by an Omron H3CRF8 repeat cycle timer. With this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120\/208\/240 VAC single phase 2 HP pumps or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14” x 12” x 6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Piezoelectric buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch. \u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/files\/ALTD2HPDV_Grinder.pdf?1634\" title=\"Click\"\u003eGrinder Pump Duplex Control Panel Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":20478587043928,"sku":"RJR-DCP-ALTD2HPDV-N01","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-2HP-DV-SecondSpin-01-01.jpg?v=1559754810"},{"product_id":"copy-of-altdm2hpdv-220v-120v-duplex-control-panel","title":"Grinder Pump Duplex Control Panel 220V ALTDM2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cp\u003eThis control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control.\u003c\/p\u003e\n\u003cp\u003eThe pump operation is controlled on demand by a three float set up. The three floats are primary pump On\/Off, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120\/208\/240 VAC single phase 2 HP pumps or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp double pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump or pumping treated effluent water from a septic holding tank to the dispersal area.  \u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14”x12”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003ch3\u003eFeatures \u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eDemand operation using pump rated wide-angle floats.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field w\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/files\/ALTDM2HPDV_Grinder.pdf?1608\" title=\"Click\"\u003eGrinder Pump Duplex Control Panel Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":20549369725016,"sku":"RJR-DCP-ALTDM2HPDV-N01","price":885.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DM2HP-DV_Control_Panel-01-02_a4669012-b11e-4854-9612-f94c8b5ae84f.jpg?v=1559755164"},{"product_id":"sewage-duplex-control-panel-220v-120v","title":"Sewage Duplex Control Panel 220V\/120V ALTDM2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cp\u003eThe ALTDM2HPDV is designed to operate a duplex lift station with alarm. This control can be used for pump up or pump down operation. This control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control. The pump operation is controlled on demand by a three float set up. The three floats are primary pump On\/Off, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eEach pump will have a 20 Amp double pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump or pumping treated effluent water from a septic holding tank to the dispersal area.  \u003c\/p\u003e\n\u003cp\u003e The enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14”x12”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eDemand operation using pump rated wide-angle floats.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/files\/ALTDM2HPDV_Sewage.pdf?1608\" title=\"Click\"\u003eSewage Pump Duplex Control Panel Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":20631029776472,"sku":"RJR-DCP-ALTDM2HPDV-N02","price":885.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DM2HP-DV_Control_Panel-01-02_62957531-0012-4143-887a-13b702549023.jpg?v=1559758508"},{"product_id":"sewage-duplex-dosing-timer-control-panel-220v-120v","title":"Sewage Duplex Dosing Timer Control Panel 220V\/120V ALTD2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cp\u003eThe ALTD2HPDV is designed to operate a duplex lift station with alarm. This control can be used for pump up or pump down operation. This control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control. The pump operation is controlled by an Omron H3CRF8 repeat cycle timer. With this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eEach pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14” x 12” x 6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Piezoelectric buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch. \u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca title=\"Click\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/files\/ALTD2HPDV_Sewage.pdf?1634\"\u003eSewage Pump Duplex Control Panel Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e","brand":"Wholesale Septic Supply","offers":[{"title":"Default Title","offer_id":20631050125400,"sku":"RJR-DCP-ALTD2HPDV-N02","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-2HP-DV-SecondSpin-01-01_06c140fb-6cc2-419f-afdf-2403e5663fdb.jpg?v=1559760948"},{"product_id":"sewage-duplex-dosing-timer-control-panel-120v","title":"Sewage Duplex Dosing Timer Control Panel 120V ALT-DT-LA","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cp\u003eThe pump operation is controlled by an Omron H3CRF8 repeat cycle timer. With this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120VAC single phase ½ HP pump or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 12”x10”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12”x10”x6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/files\/ALT-DT-LA_Sewage.pdf?1608\" title=\"Click\"\u003eSewage Pump Duplex Control Panel Documentation\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e","brand":"Wholesale Septic Supply","offers":[{"title":"Default Title","offer_id":20631069818968,"sku":"RJR-DCP-ALTDTLA-N02","price":835.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-LA_Control_Panel-01-02_77a17ce2-8c20-4785-badb-9147df01a487.jpg?v=1559760346"},{"product_id":"duplex-control-panel-220v-120v","title":"Duplex Control Panel 220V\/120V ALTDM2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e \n\u003cp\u003eThis control can be used for pump up or pump down operation. This control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control. The pump operation is controlled on demand by a three float set up. The three floats are primary pump On\/Off, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003e This control panel will operate two 120\/208\/240 VAC single phase 2 HP pumps or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp double pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump or pumping treated effluent water from a septic holding tank to the dispersal area. \u003c\/p\u003e\n\u003cp\u003e The enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14”x12”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eDemand operation using pump rated wide-angle floats.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003eP\/N: RJR-DCP-ALTDM2HPDV\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":29028928815192,"sku":"RJR-DCP-ALTDM2HPDV","price":885.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DM2HP-DV_Control_Panel-01-02_4119aab6-8464-4f01-94d5-4babc36a0c59.jpg?v=1560439732"},{"product_id":"duplex-dosing-timer-control-panel-120v","title":"Grinder Duplex Dosing Timer Control Panel 120V ALT-DT-LA","description":"\u003cul class=\"tabs\"\u003e \u003cli class=\"active\"\u003eKey Features\u003cbr\u003e \u003c\/li\u003e \u003cli\u003eSpecs\u003c\/li\u003e \u003cli\u003eWarranty\u003c\/li\u003e \u003c\/ul\u003e  \u003cul class=\"tabs-content\"\u003e \u003cli class=\"active\"\u003e\n\u003cp\u003eThe pump operation is controlled by an Omron H3CRF8 repeat cycle timer. With this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120VAC single phase ½ HP pump or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 12”x10”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12”x10”x6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003c\/li\u003e  \u003cli\u003e \u003cp\u003e\u003c\/p\u003e  \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e\u003cbr\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003cspan face=\"Helvetica Neue\" size=\"2\" color=\"#000000\"\u003eP\/N: \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003eRJR-DCP-ALTDTLA\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003cspan face=\"Helvetica Neue\" size=\"2\" color=\"#000000\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":29028931862616,"sku":"RJR-DCP-ALTDTLA-N01","price":835.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-LA_Control_Panel-01-02_78584d7d-6647-4789-9b00-28143f2cd038.jpg?v=1560439851"},{"product_id":"duplex-dosing-timer-control-panel-120v-1","title":"Duplex Dosing Timer Control Panel 120V ALT-DT-LA","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e \n\u003cp\u003eWith this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120VAC single phase ½ HP pump or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 12”x10”x6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12”x10”x6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Pizo electrical buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch.\u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan face=\"Helvetica Neue\" size=\"2\" color=\"#000000\"\u003eP\/N: \u003c\/span\u003eRJR-DCP-ALTDTLA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003cspan face=\"Helvetica Neue\" size=\"2\" color=\"#000000\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":29028931993688,"sku":"RJR-DCP-ALTDTLA","price":835.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-LA_Control_Panel-01-02_f8c8d79a-74be-425d-8e9b-916ff6af3122.jpg?v=1560439868"},{"product_id":"duplex-dosing-timer-control-panel-220v-120v","title":"Duplex Dosing Timer Control Panel 220V\/120V ALTD2HPDV","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e \n\u003cp\u003eThis control has three incoming power circuits. There will be an independent circuit for each pump and a 120 VAC circuit for the Alarm. This will allow this control to operate pumps from 120 VAC 4\/10 HP up to a 240 VAC 2 HP with one control. The pump operation is controlled by an Omron H3CRF8 repeat cycle timer. With this timer, the pumps can be operated from 1 second to 30 hours with an independent run and rest time settings. This is helpful when wanting to move small volumes of water. The three floats are Timer Enable, Alarm, and secondary pump On\/Off float. This control is a duplex pump operation and will alternate the pump load between both pumps. The control will switch pumps at the end of every pump cycle so the opposing pump will start on the next cycle. The alternating relay is switchable to lock the pump load onto either pump so if one pump needs to be removed for service or replacement the other pump will carry the full pump load.\u003c\/p\u003e\n\u003cp\u003eThis control panel will operate two 120\/208\/240 VAC single phase 2 HP pumps or smaller. There are three circuit breakers in this control. Each pump will have a 20 Amp single pole circuit breaker and the alarm uses a 10 Amp single pole circuit breaker. The alarm is designed to be used with a float switch. When the float switch closes, the 360 degrees top mounted red alarm light will come on and the Piezoelectric buzzer will sound. This control also has a latching alarm feature. This means when the Alarm float closes the alarm will stay on even if the tank returns to a normal level. This alarm must be manually reset by turning the Alarm circuit breaker off, then back on. There is an alarm test and buzzer silence switch mounted in the door of the enclosure. This control is mainly used to pump sewage from a septic holding tank to a treatment unit using a solid handling pump, or pumping treated effluent water from a septic holding tank to the dispersal area.\u003c\/p\u003e\n\u003cp\u003eThe enclosure has a NEMA rating of 4X which provides protection from falling dirt, falling liquids, hose-directed water and corrosive agents. The 14” x 12” x 6” enclosure is made of Polycarbonate and has a hinged lockable door with latches and included screws to secure the door if required. All electrical components are mounted inside the enclosure on an aluminium back plate.\u003c\/p\u003e\n\u003cp\u003eFeatures \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14” x 12” x 6” Polycarbonate Enclosure, NEMA 4X\u003c\/li\u003e\n\u003cli\u003eHinged lockable door with two latches.\u003c\/li\u003e\n\u003cli\u003eThree circuit breakers for the protection of components.\u003c\/li\u003e\n\u003cli\u003eRepeat cycle timer for time dosing effluent applications.\u003c\/li\u003e\n\u003cli\u003ePump test switch inside the enclosure to check pump operation.\u003c\/li\u003e\n\u003cli\u003eAlarm light and Piezoelectric buzzer.\u003c\/li\u003e\n\u003cli\u003eAlarm test and buzzer silence switch. \u003c\/li\u003e\n\u003cli\u003eCaptive terminal strip for field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003cspan face=\"Helvetica Neue\" size=\"2\" color=\"#000000\"\u003eP\/N: RJR-DCP-ALTD2HPDV\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":29028934910040,"sku":"RJR-DCP-ALTD2HPDV","price":975.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/ALT-DT-2HP-DV-SecondSpin-01-01_dd2ea8de-a9a3-4ba7-9f8d-ddccef62bd37.jpg?v=1560439950"},{"product_id":"alt-dmd-la-grinder-control-panel","title":"Grinder Control Panel RJR-DCP-ALTDMDLA","description":"\u003cul class=\"tabs\"\u003e \u003cli class=\"active\"\u003eKey Features\u003cbr\u003e \u003c\/li\u003e \u003cli\u003eSpecs\u003c\/li\u003e \u003cli\u003eWarranty\u003c\/li\u003e \u003c\/ul\u003e  \u003cul class=\"tabs-content\"\u003e \u003cli class=\"active\"\u003e\n\u003cp\u003eThis panel is made for 115v operations in an application with two submersible pumps. The Duplex panel RJR-DCP-ALTDMDLA will monitor and control the pumps automatically when it is set up. This will keep your pumps working as efficiently as possible, with the least amount of maintenance work possible.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA has two independent breaker rows for each pump. That way if one pump malfunctions, it should not affect the second. The panel also comes with an alarm that will alert you if there is a high amount of water in the panel or a malfunctioning pump. The panel also comes with a pump test switch to monitor if the pumps are functioning properly.\u003c\/p\u003e\n\u003cp\u003eThe warning light is 360-Degrees, so you will know of an issue regardless of where the Duplex panel RJR-DCP-ALTDMDLA is placed. The panel also has run indicator lights, so you will know the panel itself is functioning properly. If there is an issue with the panel or the pumps, there is a high decibel alarm buzzer that will ring at an ear-piercing 95 dB. Once you hear of see the alarm, there is an override circuit for testing pumps. There are also control and alarm circuit fuses.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA includes an automatic alternating relay, which alternates between which pump runs the cycle. It also includes three mechanical float switches: One Pump Hand, off, and Auto toggle.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA typically boasts an excellent life span. However, if any problems arise there is a Two Year Warranty included with your purchase!\u003c\/p\u003e\n\u003cp\u003eYou (the customer) are responsible for making sure you are following all applicable laws and regulations in your area before replacing your septic air pump yourself. Duplex panel for RJR-DCP-ALTDMDLA are Registered Trademarks of duplex panel. Under no circumstances is Wholesale Septic Supply representing to the general public that it is an Authorized Distributor, Dealer, or is affiliated with those companies with whom we make product comparisons or with any products we sell.\u003c\/p\u003e \u003c\/li\u003e  \u003cli\u003e \u003cp\u003e\u003c\/p\u003e  \u003c\/li\u003e \u003cli\u003e \u003cp\u003e\u003cbr\u003e\u003c\/p\u003e \u003c\/li\u003e \u003c\/ul\u003e\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":40047336718424,"sku":"RJR-DCP-ALTDMDLA-N01","price":725.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/CONTROL_PANEL_003_a8021ef4-7693-47d8-9c97-9bcdc1a07829.jpg?v=1661346922"},{"product_id":"alt-dmd-la-sewage-control-panel","title":"Sewage Control Panel RJR-DCP-ALTDMDLA","description":"\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eKey Features\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSpecs\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e \n\u003cp\u003eIf you’re in the market for an innovative sewage and wastewater control panel, the Duplex panel RJR-DCP-ALTDMDLA may be for you. This panel is made for 115v operations in an application with two submersible pumps. The Duplex panel RJR-DCP-ALTDMDLA will monitor and control the pumps automatically when it is set up. This will keep your pumps working as efficiently as possible, with the least amount of maintenance work possible.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA has two independent breaker rows for each pump. That way if one pump malfunctions, it should not affect the second. The panel also comes with an alarm that will alert you if there is a high amount of water in the panel or a malfunctioning pump. The panel also comes with a pump test switch to monitor if the pumps are functioning properly.\u003c\/p\u003e\n\u003cp\u003eThe warning light is 360-Degrees, so you will know of an issue regardless of where the Duplex panel RJR-DCP-ALTDMDLA is placed. The panel also has run indicator lights, so you will know the panel itself is functioning properly. If there is an issue with the panel or the pumps, there is a high decibel alarm buzzer that will ring at an ear-piercing 95 dB. Once you hear of see the alarm, there is an override circuit for testing pumps. There are also control and alarm circuit fuses.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA includes an automatic alternating relay, which alternates between which pump runs the cycle. It also includes three mechanical float switches: One Pump Hand, off, and Auto toggle.\u003c\/p\u003e\n\u003cp\u003eThe Duplex panel RJR-DCP-ALTDMDLA typically boasts an excellent life span. However, if any problems arise there is a Two Year Warranty included with your purchase!\u003c\/p\u003e\n\u003cp\u003eYou (the customer) are responsible for making sure you are following all applicable laws and regulations in your area before replacing your septic air pump yourself. Duplex panel for RJR-DCP-ALTDMDLA are Registered Trademarks of duplex panel. Under no circumstances is Wholesale Septic Supply representing to the general public that it is an Authorized Distributor, Dealer, or is affiliated with those companies with whom we make product comparisons or with any products we sell.\u003c\/p\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003c\/p\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"RJR CONTROLS","offers":[{"title":"Default Title","offer_id":40047338455128,"sku":"RJR-DCP-ALTDMDLA-N02","price":725.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/products\/CONTROL_PANEL_003_27f8fc0f-c3f8-48db-8e78-099048e6ffd1.jpg?v=1661346972"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0947\/8008\/collections\/DuplexPanel_1.png?v=1709863981","url":"https:\/\/www.wholesalesepticsupply.com\/collections\/duplex-control-panels\/rjr-controls.oembed","provider":"Wholesale Septic Supply","version":"1.0","type":"link"}